Chemical Corrosion Tables for Fiberglass Grating:

Table Legend:

  • +++ Suitable for continuous exposure to the indicated chemical environment

  • ++   Suitable for frequent splash and spill exposure to the indicated chemical environment

  • +     Suitable for incidental exposure, including occasional splashes and spills to the indicated chemical environment

  • NR - Not recommended for exposure to the indicated chemical environment

  • Max. Temp F - Maximum recommended temperature for the indicated environment

 

 

Chemical Environment

CC-Grate (ISO)

CC-Grate (VE)

Suitability

(Max. Temp. F)

Suitability

(Max. Temp. F)

 

50%

+++

150

+++

180

Acetone

100%

+

75

++

75

Alcohols

100%

NR

 

+++

120

Alum

ALL

+++

150

+++

180

Aluminum Chloride

ALL

+++

150

+++

180

Aluminum Fluoride

20%

NR

 

+++

75

Aluminum Hydroxide

ALL

++

130

+++

160

Ammonium Hydroxide

30%

NR

 

+

75

Ammonium Salts-Neutral

ALL

++

120

+++

120

Barium Salts

ALL

+++

150

+++

180

Benzene

100%

NR

 

+

140

Biodegradable Cleaner

100%

+++

100

+++

120

Black Liquor (Pulp Mill)

ALL

+

150

+++

180

Bleach Liquor (Pulp Mill)

ALL

NR

 

++

120

Calcium Hydroxide

25%

++

140

+++

170

Carbon Monoxide Gas

100%

+++

150

+++

180

Carbon Tetrachloride

100%

NR

 

+++

75

Chlorine, Wet Gas

SAT

NR

 

+++

140

Chlorine Water

SAT.

NR

 

+++

120

Chlorobenzene

100%

NR

 

++

75

Chloroform

100%

NR

 

NR

 
Copper Cyanide Plating Soln.

ALL

+

100

+++

120

Copper Salts

ALL

+++

140

+++

180

Crude Oil

100%

+++

140

+++

170

Diesel Fuel

ALL

+++

100

+++

100

Diethyl Benzene

100%

NR

 

NR

 
Ethers

100%

NR

 

NR

 
Ethylene Glycol

100%

+++

150

+++

180

Fatty Acids

SAT

+++

150

+++

180

Ferric Chloride

SAT

+++

140

+++

170

Fluoride Salt

ALL

+

75

+++

75

Formaldehyde

25%

NR

 

+++

140

Formaldehyde

100%

NR

 

NR

 
Formic Acid

25%

+

95

+++

95

Gasoline

ALL

+++

100

+++

100

Glycerine

100%

+++

140

+++

170

Green Liquor (Pulp Mill)

ALL

NR

 

+++

150

Heptane

100%

+++

130

+++

180

Hexane

100%

+

90

+++

140

Hydrochloric Acid

10%

+++

140

+++

170

Hydrochloric Acid

30%

+

140

+++

170

Hydrofluoric Acid

20%

NR

 

+++

75

Hydrogen Peroxide

30%

NR

 

+++

75

Kerosene

100%

+++

150

+++

180

Lactic Acid

100%

+++

140

+++

170

Lime Slurry

SAT.

+++

140

+++

170

Methyl Ethyl Ketone

100%

NR

 

NR

 
Mercury Chloride

100%

+++

140

+++

170

Mineral Oil

100%

+++

150

+++

180

Naphtha

100%

+++

130

+++

150

Nickel Salts

ALL

+++

140

+++

170

Nitric Acid

20%

++

120

+++

120

Nitric Acid

30%

NR

 

++

90

Ozone

ALL

+++

100

+++

100

Phenol

10%

NR

 

+++

75

Potassium Hydroxide

10%

NR

 

+++

110

Potassium Salts

ALL

+++

140

+++

170

Propylene Glycol

ALL

+++

150

+++

180

Sea Water

100%

+++

120

+++

140

Sodium Hydroxide

50%

NR

 

+++

150

Sodium Salts

ALL

+++

140

+++

170

Sulfur Dioxide

VAPOR

++

150

+++

170

Sulfuric Acid

25%

++

140

+++

170

Sulfuric Acid

50%

++

120

+++

140

Toluene

100%

NR

 

+

100

Water (Fresh, Salt, Deionized)

100%

+++

150

+++

180

White Liquor (Pulp Mill)

ALL

+

140

+++

170

Zinc Chloride

SAT.

+

75

+++

75

Zinc Salts

100%

+++

140

+++

170

Consult the manufacturer for exposure information or recommendations for temperatures or chemicals not indicated in this guide.   The information in this guide is correct to the best of the manufacturers' knowledge.  This guide is based on extrapolations of data supplied by resin manufacturers as well as service history of this product in corrosive environments.   No warranty is expressed or implied, including warranty of merchantability or fitness for any specific application. In no event will Century Composites be liable for incidental or consequential damages whether arising from alleged negligence, strict liability or otherwise.   Because actual use conditions differ and combinations of chemicals and temperatures will occur in service, the end user must test for use and applicability under actual conditions.  Test samples are available upon specific request.

 