  CenturionTM  Brand of MOLDED FIBERGLASS GRATING 

 

1-1/2" x 6" x 1-1/2" Thick

(Rectangular Mesh)

 

Corrosion Data

 

INSTALLATION NOTES: The following tables have been developed based on two sided support layouts. Caution is needed to be sure that the rectangular grating is installed with bearing bars running from support to support. All grating should be fastened to the supports using fasteners such as the CC-Clips described in this site. These should be used every 3’-4’ along the supports, with a minimum of four clips on small sections. The clips not only add safety for the employees using the grating, but also improve on the deflection noted below.

 

PHYSICAL DEFLECTION DATA

CONCENTRATED LOAD

(12" strip load)

SPAN

MAX LOAD

(lb/sf)

LOAD

(lb)

Inch

Normal

Firm

100

200

500

1000

2000

12

>3000

>3000

*

*

0.019

0.039

0.078

18

>3000

2513

0.010

0.020

0.050

0.099

0.199

24

1705

1136

0.022

0.044

0.110

0.220

0.441

36

518

345

0.072

0.145

0.362

*

*

48

266

177

0.141

0.282

*

*

*

 

UNIFORM LOAD

(entire panel load)

SPAN

MAX LOAD

(lb/sf)

LOAD

(lb/sf)

Inch

Normal

Firm

50

100

150

200

250

12

>3000

>3000

*

*

*

*

*

18

>3000

2460

*

*

0.014

0.019

0.023

24

1359

807

0.014

0.028

0.041

0.055

0.069

36

276

162

0.067

0.136

0.204

0.272

0.339

48

107

71

0.176

0.353

*

*

*

 

POINT LOAD

(center of panel)

"Normal" is the load (in pounds) that will produce a deflection of 0.375" (accepted as providing a "Normal" feel for foot traffic).

"Firm" is the load (in pounds) that will produce a deflection of 0.250" (accepted as providing a "Firm" feel for foot traffic).

 

All deflections are presented in inches. Loads are presented in pounds

SPAN

LOAD

(lb)

Inch

Normal

Firm

12

>3000

>3000

18

>3000

>3000

24

>3000

2224

36

1360

827

48

781

510

Deflections less than 0.010" and greater than 0.500" have been omitted.   The use of various resins, reinforcements and surfaces can result is variations of up to 15% in load data.    Free span width for 48" span data is 2" less than width of grating.   This information is provided as a guide to the use and application of CC-Grate and is not or does not represent a specific warranty of the product or its performance.    The designer or user must determine the suitability of this product for a specific application.

 

Call for information or email:   sales@centuryfrpgrating.com  