Site Map      

Home Page

Links   

Company History

 

Molded Fiberglass Grating

Pultruded Fiberglass Grating

Decktop FRP Grating

Grit-Plate

Stair Treads

Tread Covers

Clips - Holddowns

Custom Capabilities

Contact Century

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CenturionTM  Brand of MOLDED FIBERGLASS GRATING

 

1-1/2" x 1-1/2" x 1" Thick

(Square Mesh)

 

Corrosion Data

 

INSTALLATION NOTES: The following tables have been developed based on two sided support layouts. Caution is needed to be sure that the rectangular grating is installed with bearing bars running from support to support. All grating should be fastened to the supports using fasteners such as the CC-Clips described in this site. These should be used every 3’-4’ along the supports, with a minimum of four clips on small sections. The clips not only add safety for the employees using the grating, but also improve on the deflection noted below.

PHYSICAL DEFLECTION DATA

CONCENTRATED LOAD

(12" strip load)

SPAN

MAX LOAD

(lb/sf)

LOAD

(lb)

Inch

Normal

Firm

100

200

500

1000

2000

12

2640

1758

0.014

0.029

0.070

0.143

0.284

18

871

573

0.047

0.092

0.219

0.429

*

24

414

279

0.093

0.177

0.454

*

*

36

125

83

0.300

*

*

*

*

48

92

60

*

*

*

*

*

 

UNIFORM LOAD

(entire panel load)

SPAN

MAX LOAD

(lb/sf)

LOAD

(lb/sf)

Inch

Normal

Firm

50

100

150

200

250

12

>3000

2520

*

*

0.013

0.018

0.023

18

927

615

0.022

0.043

0.064

0.084

0.104

24

328

221

0.058

0.111

0.168

0.226

0.284

36

77

52

0.242

*

*

*

*

48

40

30

*

*

*

*

*

 

POINT LOAD

(center of panel)

"Normal" is the load (in pounds) that will produce a deflection of 0.375" (accepted as providing a "Normal" feel for foot traffic).

"Firm" is the load (in pounds) that will produce a deflection of 0.250" (accepted as providing a "Firm" feel for foot traffic).

 

All deflections are presented in inches. Loads are presented in pounds

SPAN

LOAD

(lb)

Inch

Normal

Firm

12

2789

1863

18

1740

1157

24

951

632

36

371

233

48

246

166

Deflections less than 0.010" and greater than 0.500" have been omitted.   The use of various resins, reinforcements and surfaces can result is variations of up to 15% in load data.    Free span width for 48" span data is 2" less than width of grating.   This information is provided as a guide to the use and application of CC-Grate and is not or does not represent a specific warranty of the product or its performance.    The designer or user must determine the suitability of this product for a specific application.

Call for information or email:   sales@centuryfrpgrating.com  

140 Celtic Blvd. - Tyrone, GA 30290 - Phone: 770-632-7112 - Fax: 770-632-7115